Titel: | 7T MR neurography-ultrasound fusion for peripheral nerve imaging |
Autor(en): | Schreiber, Stefanie Schreiber, Frank Peter, Alica Isler, Eser Dörner, Marc Heinze, Hans-Jochen Petri, Susanne Tempelmann, Claus Nestor, Peter J. Grimm, Alexander Vielhaber, Stefan |
Erscheinungsdatum: | 2020 |
Art: | Artikel |
Sprache: | Englisch |
URN: | urn:nbn:de:gbv:ma9:1-1981185920-873172 |
Schlagwörter: | CMT1A Fusion imaging Magnetic resonance neurography Microvascular blood flow Ultrasound |
Zusammenfassung: | Background: We present one patient with an initial diagnosis of Guillain-Barré syndrome (GBS) and one with Charcot–Marie–Tooth disease (CMT) type 1A. Methods: Both patients underwent ankle tibial nerve fusion-imaging of highresolution ultrasound (HRUS) with 7T MR neurography (MRN). Results: In GBS, the nerve was enlarged, T2-hyperintense, and showed increased vascularization 21 months after symptom onset. In CMT1A, the enlarged nerve was T2-isointense with normal endoneurial blood flow. Conclusions: We demonstrate the utility of 7T-MRN-HRUS-fusion-imaging. In GBS, there was evidence of ongoing inflammation resulting in a changed diagnosis to acute-onset chronic demyelinating polyradiculoneuropathy and maintenance of immunotherapy. By MRN-HRUS-fusion, patients with presumed peripheral axonal degeneration could be shown to display imaging markers associated with peripheral nervous system inflammation. Thus, more accurate identification of a treatable inflammatory component may become possible. |
URI: | https://opendata.uni-halle.de//handle/1981185920/87317 http://dx.doi.org/10.25673/85365 |
Open-Access: | Open-Access-Publikation |
Nutzungslizenz: | (CC BY-NC 4.0) Creative Commons Namensnennung - Nicht kommerziell 4.0 International |
Sponsor/Geldgeber: | Projekt DEAL 2020 |
Journal Titel: | Muscle & nerve |
Verlag: | Wiley |
Verlagsort: | New York, NY [u.a.] |
Band: | 61 |
Heft: | 4 |
Originalveröffentlichung: | 10.1002/mus.26800 |
Seitenanfang: | 521 |
Seitenende: | 526 |
Enthalten in den Sammlungen: | Medizinische Fakultät (OA) |