Bitte benutzen Sie diese Kennung, um auf die Ressource zu verweisen: http://dx.doi.org/10.25673/117095
Titel: Characterization of PLGA versus PEG-PLGA intracochlear drug delivery implants : degradation kinetics, morphological changes, and pH alterations
Autor(en): Lehner, EricIn der Gemeinsamen Normdatei der DNB nachschlagen
Liebau, Arne
Menzel, Matthias
Schmelzer, ChristianIn der Gemeinsamen Normdatei der DNB nachschlagen
Knolle, Wolfgang
Scheffler, JonasIn der Gemeinsamen Normdatei der DNB nachschlagen
Binder, Wolfgang H.In der Gemeinsamen Normdatei der DNB nachschlagen
Plontke, Stefan K.-R.In der Gemeinsamen Normdatei der DNB nachschlagen
Mäder, KarstenIn der Gemeinsamen Normdatei der DNB nachschlagen
Erscheinungsdatum: 2024
Art: Artikel
Sprache: Englisch
Zusammenfassung: Drug delivery to the inner ear presents a unique challenge due to the complex inner ear anatomy and its tight physiological barriers. This study investigates the degradation behavior of intracochlear drug delivery implants (IDDI) composed of dexamethasone and poly(lactic-co-glycolic acid) (PLGA) or polyethylene glycol–poly(lactic-co-glycolic acid) (PEG-PLGA), respectively. IDDI were incubated in artificial perilymph and implants' degradation kinetics, morphological changes, water uptake behavior, and pH alterations were assessed. Microscopy revealed significant changes in appearance, with PLGA IDDI exhibiting rapid expansion, reaching up to 183 % in diameter and 185 % in length. PEG-PLGA implants showed gradual expansion, reaching a maximum of 178 % in diameter and 144 % in length. Despite these morphological changes, the IDDIs could still be applicable in terms of cochlear dimensions in combination with cochlear implants (CI) in humans or in a domestic pig animal model. Scanning electron microscopy analysis demonstrated surface alterations of PLGA implants, while PEG-PLGA implants remained shape-stable. Gravimetric analysis and gel permeation chromatography revealed distinct degradation profiles, with PLGA implants displaying rapid water uptake and mass loss, while PEG-PLGA implants showed delayed water uptake and minimal mass reduction. pH measurements using the pH-sensitive fluorescent dye SNARF™-1 showed initial pH reduction in artificial perilymph for PLGA implants while PEG-PLGA implants maintained pH stability.
URI: https://opendata.uni-halle.de//handle/1981185920/119055
http://dx.doi.org/10.25673/117095
Open-Access: Open-Access-Publikation
Nutzungslizenz: (CC BY 4.0) Creative Commons Namensnennung 4.0 International(CC BY 4.0) Creative Commons Namensnennung 4.0 International
Journal Titel: Journal of drug delivery science and technology
Verlag: Ed. de Santé
Verlagsort: Paris
Band: 99
Originalveröffentlichung: 10.1016/j.jddst.2024.105972
Seitenanfang: 1
Seitenende: 9
Enthalten in den Sammlungen:Open Access Publikationen der MLU

Dateien zu dieser Ressource:
Datei Beschreibung GrößeFormat 
1-s2.0-S1773224724006415-main.pdf6.04 MBAdobe PDFMiniaturbild
Öffnen/Anzeigen