Bitte benutzen Sie diese Kennung, um auf die Ressource zu verweisen: http://dx.doi.org/10.25673/92679
Titel: Quantitative evaluation of prospective motion correction in healthy subjects at 7T MRI
Autor(en): Sciarra, Alessandro
Mattern, HendrikIn der Gemeinsamen Normdatei der DNB nachschlagen
Yakupov, Renat
Chatterjee, Soumick
Stucht, Daniel
Oeltze-Jafra, Steffen
Godenschweger, FrankIn der Gemeinsamen Normdatei der DNB nachschlagen
Speck, OliverIn der Gemeinsamen Normdatei der DNB nachschlagen
Erscheinungsdatum: 2022
Art: Artikel
Sprache: Englisch
URN: urn:nbn:de:gbv:ma9:1-1981185920-946316
Schlagwörter: High-resolution structural MRI
Image quality assessment
Optical motion tracking system
PMC
Ultrahigh field
Zusammenfassung: Purpose Quantitative assessment of prospective motion correction (PMC) capability at 7T MRI for compliant healthy subjects to improve high-resolution images in the absence of intentional motion. Methods Twenty-one healthy subjects were imaged at 7 T. They were asked not to move, to consider only unintentional motion. An in-bore optical tracking system was used to monitor head motion and consequently update the imaging volume. For all subjects, high-resolution T1 (3D-MPRAGE), T2 (2D turbo spin echo), proton density (2D turbo spin echo), and urn:x-wiley:07403194:media:mrm28998:mrm28998-math-0001 (2D gradient echo) weighted images were acquired with and without PMC. The images were evaluated through subjective and objective analysis. Results Subjective evaluation overall has shown a statistically significant improvement (5.5%) in terms of image quality with PMC ON. In a separate evaluation of every contrast, three of the four contrasts (T1, T2, and proton density) have shown a statistically significant improvement (9.62%, 9.85%, and 9.26%), whereas the fourth one (urn:x-wiley:07403194:media:mrm28998:mrm28998-math-0002) has shown improvement, although not statistically significant. In the evaluation with objective metrics, average edge strength has shown an overall improvement of 6% with PMC ON, which was statistically significant; and gradient entropy has shown an overall improvement of 2%, which did not reach statistical significance. Conclusion Based on subjective assessment, PMC improved image quality in high-resolution images of healthy compliant subjects in the absence of intentional motion for all contrasts except urn:x-wiley:07403194:media:mrm28998:mrm28998-math-0003, in which no significant differences were observed. Quantitative metrics showed an overall trend for an improvement with PMC, but not all differences were significant.
URI: https://opendata.uni-halle.de//handle/1981185920/94631
http://dx.doi.org/10.25673/92679
Open-Access: Open-Access-Publikation
Nutzungslizenz: (CC BY-NC 4.0) Creative Commons Namensnennung - Nicht kommerziell 4.0 International(CC BY-NC 4.0) Creative Commons Namensnennung - Nicht kommerziell 4.0 International
Sponsor/Geldgeber: Projekt DEAL 2021
Journal Titel: Magnetic resonance in medicine
Verlag: Wiley-Liss
Verlagsort: New York, NY [u.a.]
Band: 87
Heft: 2
Originalveröffentlichung: 10.1002/mrm.28998
Seitenanfang: 646
Seitenende: 657
Enthalten in den Sammlungen:Medizinische Fakultät (OA)

Dateien zu dieser Ressource:
Datei Beschreibung GrößeFormat 
Sciarra et al._Quantitative evaluation_2022.pdfZweitveröffentlichung2.41 MBAdobe PDFMiniaturbild
Öffnen/Anzeigen