Please use this identifier to cite or link to this item:
http://dx.doi.org/10.25673/802
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.referee | Boeckler, PD Dr. | - |
dc.contributor.referee | Schaller, Prof. Dr. | - |
dc.contributor.referee | Geis-Gerstorfer, Prof. Dr. | - |
dc.contributor.author | Blümel, Nadine | - |
dc.date.accessioned | 2018-09-24T10:43:31Z | - |
dc.date.available | 2018-09-24T10:43:31Z | - |
dc.date.issued | 2012 | - |
dc.identifier.uri | https://opendata.uni-halle.de//handle/1981185920/7702 | - |
dc.identifier.uri | http://dx.doi.org/10.25673/802 | - |
dc.description.abstract | Anhand werkstoffkundlicher Parameter sollte geklärt werden, ob die Desinfektion materialtechnische Eigenschaften von PMMA Kunststoffen beeinflusst. Es mangelt an einem ausreichenden Produktangebot. Material und Methoden: Prüfkörper der Kunststoffe PalaXpress [PX], Paladon65 [PD], Futura Gen [FG] und FuturAcryl [FA] wurden hergestellt, die mit Impresept [IM], Stammopur DR (SP) und D050 Instru-Gen [IG] desinfiziert wurden. Ermittelt wurden Biegeeigenschaften, Makro-, Mikrohärte, Rauigkeits- und Farbänderungen nach Desinfektionsmitteleinwirkung. Ergebnisse: SP erhöhte die Rauigkeit von PX. IG bewirkte eine subjektiv wahrnehmbare Farbänderung bei FA (∆E>2). Die Parameter Elastizität, Festigkeit und Makrohärte blieben unbeeinflusst. Nach Desinfektion von PX und GF ergaben sich teilweise erhöhte Mikrohärtewerte. Zusammenfassung: In Bezug auf die aktuell erarbeiteten Ergebnisse kann IM zur Prothesendesinfektion im Sinne einer Erweiterung des Anwendungsspektrums und der Vereinheitlichung von Arbeitsabläufen empfohlen werden. | - |
dc.description.abstract | This study investigated the influence of chemical disinfectant solutions on several mechanical properties. There are no special products offered, which are appropriate for cleaning and disinfecting dentures. Method: Specimens of 4 denture base resins (PalaXpress [PX], Paladon65 [PD], Futura Gen [FG] and FuturAcryl [FA]) were prepared and disinfected by Impresept [IM], Stammopur DR (SP) and D050 Instru-Gen [IG]. Flexural properties, microhardness, macrohardness, changes in surface roughness and colour were determined after disinfection. Results: SP caused an increase of surface roughness of PX. FA disinfected by IG showed distinctly colour changes (∆E>2). Flexural properties and macrohardness stayed unaffected. For PX and FG an increase in microhardness was partially observed after disinfection. Conclusion: The application of IM on dental prostheses can be recommended under practical conditions in order to simplify disinfection procedures in every day practise. | eng |
dc.description.statementofresponsibility | von Nadine Blümel | - |
dc.format.extent | Online-Ressource (86 Bl. = 0,93 mb) | - |
dc.language.iso | ger | - |
dc.publisher | Universitäts- und Landesbibliothek Sachsen-Anhalt | - |
dc.rights.uri | http://rightsstatements.org/vocab/InC/1.0/ | - |
dc.subject | Online-Publikation | - |
dc.subject | Hochschulschrift | - |
dc.subject.ddc | 617 | - |
dc.title | Der Einfluss von Desinfektionsmitteln auf die klinischen Eigenschaften von Prothesenkunststoffen | - |
dcterms.dateAccepted | 2012-11-07 | - |
dcterms.type | Hochschulschrift | - |
dc.type | PhDThesis | - |
dc.identifier.urn | urn:nbn:de:gbv:3:4-8943 | - |
local.publisher.universityOrInstitution | Martin-Luther-Universität Halle-Wittenberg | - |
local.subject.keywords | chemische Desinfektion; Prothesenbasiskunststoffe; Biegefestigkeit; Mikrohärte; Makrohärte; Oberflächenrauigkeit; Farbänderung | - |
local.subject.keywords | disinfection; denture base resin; flexural strength; microhardness; macrohardness; surface roughness; colour stability | eng |
local.openaccess | true | - |
dc.identifier.ppn | 733448763 | - |
local.accessrights.dnb | free | - |
Appears in Collections: | Chirurgie und verwandte medizinische Fachrichtungen |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
2012-11-27 Promotion.pdf | 953.98 kB | Adobe PDF | View/Open |