dc.description.abstractHauptgrund für das erhöhte kardiovaskuläre Risiko chronischer Dialysepatienten ist die chronische Inflammation. Wir untersuchten die großporigere High-Cut-off-Membran (HCO 1100 der Firma Gambro). In einer zweiarmig, doppelblind, randomisierten Crossover-Studie wurde an 19 Patienten untersucht, ob durch die HCO-Membran Inflammationsmediatoren vermehr eliminiert werden können. Es zeigten sich keine signifikanten Absenkungen der gemessenen Zytokine oder der Monozytensubpopulationen beziehungsweise deren ACE-Besatz. Allerdings weist ein, am ehesten reaktiver, Anstieg der Absolutzahlen der Mo1 Subpopulation nach Behandlung mit der HCO-Membran auf mögliche Effekte hin. Die Membran zeigte eine gute Verträglichkeit. Es zeigte sich eine signifikante Albuminsenkung durch die HCO-Membran, die allerdings nicht substitutionspflichtig wurde. Die Ergebnisse dieser Pilotstudie fordern die Weiterentwicklung selektiverer High-Cut-off-Dialysatoren mit einer größeren Membranoberfläche. Somit kann die Dialyseeffektivität gesteigert und Albuminverluste gesenkt werden, wodurch die Membran über einen längeren Zeitraum anwendbar ist.-
dc.description.abstractOne of the main reason for the increased cardiovascular risk of patients with long-term hemodialysis is chronic inflammation. We tested the High-Cut-off-Membrane (HCO 1100 a product of the Gambro company), which has larger pores than other membranes. In a randomized double-blind crossover trial study, 19 patients were enrolled. The analysis showed no significant decrease of the cytokines, the monocytes subpopulations and the ACE-expression. However, a tendential increase of the Mo1 absolute cell number indicates possible effects of the HCO-Membrane. The HCO-membrane showed a good tolerability. The significant decrease of the serum albumin did not require substitution. The results of this pilot study invite for further development of more selective HCO-membranes with a larger surface area. Those larger membranes would possibly lead to increased dialysis efficiency and in a reduction of albumin losses. Also, they would likely extend the application time of the membrane.eng
dc.description.statementofresponsibilityvon Felix Neugebauer-
dc.format.extentOnline-Ressource (87 Bl. = 1,24 mb)-
dc.language.isoger-
dc.publisherUniversitäts- und Landesbibliothek Sachsen-Anhalt-
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/-
dc.subjectOnline-Publikation-
dc.subjectHochschulschrift-
dc.subject.ddc612-
dc.titleDer Einfluss der neuen HCO-1100 Dialysemembran auf das kardiovaskuläre Entzündungsgeschehen bei Dialysepatienten mit CRP Erhöhung-
dcterms.dateAccepted2014-05-19-
dcterms.typeHochschulschrift-
dc.typePhDThesis-
dc.identifier.urnurn:nbn:de:gbv:3:4-12108-
local.publisher.universityOrInstitutionMartin-Luther-Universität Halle-Wittenberg-
local.subject.keywordsHigh-cut-off Membran; Monozytensubpopulationen; chronische Inflammation; kardiovaskuläres Risiko; Dialysepatienten-
local.subject.keywordshigh-cut-off Membran; chronic inflammation; long-term hemodialysis; monocytes subpopulations; cardiovascular riskeng