Please use this identifier to cite or link to this item: http://dx.doi.org/10.25673/14081
Full metadata record
DC FieldValueLanguage
dc.contributor.refereeWerdan, Karl-
dc.contributor.refereeEbelt, Henning-
dc.contributor.refereeKaragiannidis, Christian-
dc.contributor.authorKriebel, Philipp-
dc.date.accessioned2019-09-05T11:40:43Z-
dc.date.available2019-09-05T11:40:43Z-
dc.date.issued2019-
dc.identifier.urihttps://opendata.uni-halle.de//handle/1981185920/14216-
dc.identifier.urihttp://dx.doi.org/10.25673/14081-
dc.description.abstractZur Quantifizierung der Herzleistung bei septischer Kardiomyopathie sind bislang keine geeigneten Instrumente verfügbar. Die „Afterload-related Cardiac Performance“ (ACP), welche das Herzzeitvolumen in Relation zum systemischen Gefäßwiderstand berücksichtigt, zeigte in früheren Untersuchungen einen guten prädiktiven Wert. Ziel der vorliegenden Dissertation war es, Einflüsse der Hämodynamik-Messmethode auf die prognostische Aussagekraft des ACP bei septischen Patienten in Bezug auf die Krankenhausletalität zu identifizieren. Es wurde eine prospektive, monozentrische Beobachtungsstudie mit n=137 Patienten über einen Zeitraum von 15 Monaten auf einer internistischen Intensivstation durchgeführt. Die Messung der Hämodynamikparameter erfolgte invasiv jeweils mittels Pulmonalarterienkatheter (n=39) oder mittels PiCCO-System (n=98). In der Subgruppe PiCCO konnten signifikante Unterschiede der Überlebensrate nach Kaplan-Meyer sowie der ROC-Analysen zwischen Patienten mit normalem (> 80%) und eingeschränktem (≤ 80%) ACP erbracht werden. Für Patienten mit PAK hingegen konnte das Signifikanzniveau nicht erlangt werden.ger
dc.description.abstractThere are no sufficient instruments to quantify cardiac performance in septic cardiomyopathy so far. The “Afterload-related Cardiac Performance” (ACP), which takes the cardiac output in relation to the systemic vascular resistance, provided a good predictive value in former studies. Our primary aim was to identify potential influences of hemodynamic methods on the prognostic value of ACP in relation to the in-hospital lethality in patients with severe sepsis. Therefore, a prospective, monocentric observation study including n=137 patients in a medical intensive care unit was performed for about 15 months. The invasive measurement of hemodynamic parameters was done with either pulmonary artery catheter (n=39) or PiCCO-system (n=98). Using Kaplan-Meyer- and ROC-analysis a significant difference between patients with regular (>80%) and impaired (≤ 80%) ACP could be shown for the subgroup PiCCO. In contrast to this no significant results could be reached for the subgroup PAC.eng
dc.format.extent1 Online-Ressource (87 Seiten)-
dc.language.isoger-
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/-
dc.subject.ddc610-
dc.titleEinfluss der Hämodynamik-Messmethode auf die prognostische Aussagekraft des ACP (Afterload-related Cardiac Performance) bei kritisch kranken Patienten mit Sepsis in Bezug auf die Krankenhausletalitätger
dcterms.dateAccepted2019-08-26-
dcterms.typeHochschulschrift-
dc.typePhDThesis-
dc.identifier.urnurn:nbn:de:gbv:3:4-1981185920-142164-
local.versionTypepublishedVersion-
local.publisher.universityOrInstitutionMartin-Luther-Universität Halle-Wittenberg-
local.subject.keywordsACP-Score, Sepsis, septischer Schock, septische Kardiomyopathie, erweitertes hämodynamisches Monitoring, PiCCO-System, Pulmonalarterienkatheter-
local.subject.keywordsACP-score, sepsis, septic shock, septic cardiomyopathy, extended hemodynamic monitoring, PiCCO-system, pulmonary artery catheter-
local.openaccesstrue-
dc.identifier.ppn1676025472-
local.accessrights.dnbfree-
Appears in Collections:Medizin und Gesundheit

Files in This Item:
File Description SizeFormat 
Dissertation finale Version, 28.01.2019 mit Gutachtern, ohne CV.pdf1.15 MBAdobe PDFThumbnail
View/Open