Please use this identifier to cite or link to this item: http://dx.doi.org/10.25673/101314
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBerg, Philipp-
dc.contributor.authorBehrendt, Benjamin-
dc.contributor.authorVoß, Samuel-
dc.contributor.authorBeuing, Oliver-
dc.contributor.authorNeyazi, Belal-
dc.contributor.authorSandalcioglu, I. Erol-
dc.contributor.authorPreim, Bernhard-
dc.contributor.authorSaalfeld, Sylvia-
dc.date.accessioned2023-03-07T12:52:04Z-
dc.date.available2023-03-07T12:52:04Z-
dc.date.issued2021-
dc.date.submitted2021-
dc.identifier.urihttps://opendata.uni-halle.de//handle/1981185920/103269-
dc.identifier.urihttp://dx.doi.org/10.25673/101314-
dc.description.abstractPurpose—For the status evaluation of intracranial aneurysms (IAs), morphological and hemodynamic parameters can provide valuable information. For their extraction, a separation of the aneurysm sac from its parent vessel is required that yields the neck curve and the ostium. However, manual and subjective neck curve and ostium definitions might lead to inaccurate IA assessments. Methods—The research project VICTORIA was initiated, allowing users to interactively define the neck curve of five segmented IA models using a web application. The submitted results were qualitatively and quantitatively compared to identify the minimum, median and maximum aneurysm surface area. Finally, image-based blood flow simulations were carried out to assess the effect of variable neck curve definitions on relevant flow- and shear-related parameters. Results—In total, 55 participants (20 physicians) from 18 countries participated in VICTORIA. For relatively simple aneurysms, a good agreement with respect to the neck curve definition was found. However, differences among the participants increased with increasing complexity of the aneurysm. Furthermore, it was observed that the majority of participants excluded any small arteries occurring in the vicinity of an aneurysm. This can lead to non-negligible deviations among the flow- and shear-related parameters, which need to be carefully evaluated, if quantitative analysis is desired. Finally, no differences between participants with medical and non-medical background could be observed. Conclusions—VICTORIAs findings reveal the complexity of aneurysm neck curve definition, especially for bifurcation aneurysms. Standardization appears to be mandatory for future sac-vessel-separations. For hemodynamic simulations a careful neck curve definition is crucial to avoid inaccuracies during the quantitative flow analysis.eng
dc.description.sponsorshipProjekt DEAL 2021-
dc.language.isoeng-
dc.relation.ispartofhttp://link.springer.com/journal/13239-
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/-
dc.subjectIntracranial aneurysmeng
dc.subjectNeck curveeng
dc.subjectRupture risk assessmenteng
dc.subjectHemodynamicseng
dc.subjectVICTORIAeng
dc.subject.ddc000-
dc.titleVICTORIA : VIrtual neck Curve and True Ostium Reconstruction of Intracranial Aneurysmseng
dc.typeArticle-
dc.identifier.urnurn:nbn:de:gbv:ma9:1-1981185920-1032691-
local.versionTypepublishedVersion-
local.bibliographicCitation.journaltitleCardiovascular engineering and technology-
local.bibliographicCitation.volume12-
local.bibliographicCitation.issue4-
local.bibliographicCitation.pagestart454-
local.bibliographicCitation.pageend465-
local.bibliographicCitation.publishernameSpringer-
local.bibliographicCitation.publisherplaceNew York, NY-
local.bibliographicCitation.doi10.1007/s13239-021-00535-w-
local.openaccesstrue-
dc.identifier.ppn1760994383-
local.bibliographicCitation.year2021-
cbs.sru.importDate2023-03-07T12:46:20Z-
local.bibliographicCitationEnthalten in Cardiovascular engineering and technology - New York, NY : Springer, 2010-
local.accessrights.dnbfree-
Appears in Collections:Fakultät für Informatik (OA)

Files in This Item:
File Description SizeFormat 
Berg et al._VICTORIA_2021.pdfZweitveröffentlichung2.26 MBAdobe PDFThumbnail
View/Open