Please use this identifier to cite or link to this item: http://dx.doi.org/10.25673/100094
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDillner, Jasmin-
dc.contributor.authorMeyer, Frank-
dc.contributor.authorHalloul, Zuhir-
dc.contributor.authorGörtler, Michael-
dc.date.accessioned2023-02-02T10:53:30Z-
dc.date.available2023-02-02T10:53:30Z-
dc.date.issued2021-
dc.date.submitted2021-
dc.identifier.urihttps://opendata.uni-halle.de//handle/1981185920/102050-
dc.identifier.urihttp://dx.doi.org/10.25673/100094-
dc.description.abstractZiel Der Wert der intraoperativen Angiographie und deren Ad-hoc-Beurteilung im Hinblick auf operationstechnische Unzulänglichkeiten soll geprüft werden. Methode Insgesamt 523 konsekutive A.-cartotis-Thrombendarteriektomie(TEA)-Patienten mit intraoperativer Kontrollangiographie, postoperativer Duplexsonographie und retrospektiver Zweitbeurteilung der Angiographie wurden in die Auswertung einbezogen. Ergebnisse In der retrospektiven Zweitbeurteilung der Angiographie wurden 23 (4,4%) Verschlüsse oder hochgradige Stenosen der Arteria carotis communis (ACC) oder Arteria carotis interna (ACI) im Operationsbereich (12/2,3%) bzw. in der Abstrombahn (distale extrakranielle und intrakranielle ACI, A. cerebri media [ACM]) detektiert (11/2,1%), wohingegen bei der intraoperativen Ad-hoc-Beurteilung nur 13 (2,5%) derartige Pathologien beschrieben worden waren (7/1,3% im Operationsbereich, 6/1,1% in der Abstrombahn; p=0,002). Duplexsonographisch wurden postoperativ bei 50 von 505 untersuchten Patienten (10,1%) operationstechnische Unzulänglichkeiten lokal detektiert, was signifikant mehr war als in der Angiographie (p<0,001). In den meisten Fällen handelte es sich um nicht okkludierende/nicht hochgradig stenosierende Intima-Media-Ablösungen (19), Nahteinziehungen (13) und Kinkings/Kalibersprünge am distalen Patchende (14). Nahteinziehungen und Kinkings/Kalibersprünge waren mit einer linksseitigen TEA (adjustierte OR: 2,4; 95%-KI: 1,1‑5,1), einer Operation ohne Patch (adjustierte OR: 16,6; 95%-KI: 1,3–215,0) und der Verwendung eines Dacron- vs. Polytetrafluorethylen-Patch (adjustierte OR: 3,0; 95%-KI: 1,4–6,6) assoziiert. Schlussfolgerung Bei der Ad-hoc-Beurteilung der intraoperativen Kontrollangiographie kann eine nicht unerhebliche Zahl auch okkludierender und hochgradig stenosierender Pathologien übersehen werden (zur Detektion nicht okkludierender und nicht hochgradig stenosierender operativer Unzulänglichkeiten methodisch nicht geeignet – Ausweich: postoperative Duplexsonographie).ger
dc.description.abstractAim To investigate the value of intraoperative angiography and its ad hoc evaluation with respect to cases of surgical technical inaccessibility. Methods Overall, 523 consecutive carotid artery thrombendarterectomy (TEA) patients with intraoperative control angiography, postoperative color-coded duplex sonography and retrospective re-evaluation of documented angiographic images were included in the evaluation. Results In the retrospective angiographic re-evaluation 23 (4.4%) occlusions or high-grade stenoses of the common carotid artery (CCA) or internal carotid artery (ICA) in the surgical field (12, 2.3%) or of downstream ICA or middle cerebral artery (MCA, 11, 2.1%) were detected. The detection rate was significantly lower in the intraoperative ad hoc evaluation with overall only 13 (2.5%) detected pathologies (7, 1.3% in the surgical field, 6, 1.1% in large downstream arteries, p=0.002). Postoperative duplex sonography performed in 505 patients detected 50 cases (10.1%) of local surgical technical inaccessibility, which was significantly more than in the angiography (p<0.001). In most cases these were nonocclusive, low-grade stenosing detachments of the intima media (n=19), 13 suture contractions, and 14 kinking/abrupt diameter changes at the distal end of the patch. Suture contractions and kinking/diameter changes were associated with a left-sided TEA (adjusted odds ratio, OR 2.4, 95% confidence interval, CI 1.1–5.1), an operation without a patch (adjusted OR, 16.6, 95% CI 1.3–215.0), and using Dacron patches in contrast to PTFE patches (adjusted OR 3.0, 95% CI 1.4–6.6). Conclusion The ad hoc evaluation of intraoperative completion angiography by surgeons missed a substantial number also of occluding and severely stenosing pathologies. Angiography is not suitable for the detection of nonocclusive and low-grade stenosing cases of operative inaccessibility. Postoperative color-coded duplex sonography is an adequate tool for surgical quality control.eng
dc.description.sponsorshipProjekt DEAL 2021-
dc.language.isoger-
dc.relation.ispartofhttp://link.springer.com/journal/104-
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/-
dc.subjectA.-carotis-Desobliterationger
dc.subjectDuplexsonographieger
dc.subjectPostoperatives Komplikationsprofilger
dc.subjectOutcomeeng
dc.subjectMorbiditätger
dc.subject.ddc610.72-
dc.titleIntraoperative Angiographie bei A.-carotis-Rekonstruktion : pathologische Befunde, Zuverlässigkeit und Bedeutung des Verfahrensger
dc.typeArticle-
dc.title.translatedIntraoperative angiography in carotid artery reconstruction : pathological findings, reliability and importance of the procedure-
dc.identifier.urnurn:nbn:de:gbv:ma9:1-1981185920-1020500-
local.versionTypepublishedVersion-
local.bibliographicCitation.journaltitleDer Chirurg-
local.bibliographicCitation.volume92-
local.bibliographicCitation.issue12-
local.bibliographicCitation.pagestart1123-
local.bibliographicCitation.pageend1131-
local.bibliographicCitation.publishernameSpringer-
local.bibliographicCitation.publisherplaceBerlin-
local.bibliographicCitation.doi10.1007/s00104-021-01403-y-
local.openaccesstrue-
dc.identifier.ppn1778003435-
local.bibliographicCitation.year2021-
cbs.sru.importDate2023-02-02T10:48:27Z-
local.bibliographicCitationEnthalten in Der Chirurg - Berlin : Springer, 1996-
local.accessrights.dnbfree-
Appears in Collections:Medizinische Fakultät (OA)

Files in This Item:
File Description SizeFormat 
Dillner et al._Intraoperative_2021.pdfZweitveröffentlichung334.18 kBAdobe PDFThumbnail
View/Open